Environmental Characteristics
| Temperature cycling |
-20 °C +70 °C / -4 °F +158 °F |
| Temperature cycling acceptance criteria |
Δα ≤ 0,15 dB, reversible |
| Temperature cycling test method |
IEC 60794-1-22:F1 |
| Reversible temperature cycling |
-25 °C +70 °C / -13 °F +158 °F |
| Reversible temperature cycling test method |
IEC 60794-1-22:F1 |
| Operation temperature |
-20 °C to +70 °C / -4 °F to +158 °F |
| Storage / Transport temperature |
-25 °C to +70 °C / -13 °F to +158 °F |
| Thermal load |
0.86 MJ/m |
| 2015 / 863 / EU - RoHS 3 |
Pass |
Mechanical Data
| In-service tensile strength |
300 N |
| In-service tensile strength acceptance criteria |
Δα ≤ 0,05 dB after test |
| In-service tensile strength test method |
IEC 60794-1-21:E1 |
| Installation tensile strength |
1000 N |
| Installation tensile strength acceptance criteria |
Δα ≤ 0,05 dB |
| Installation tensile strength test method |
IEC 60794-1-21:E1 |
| Crush resistance long term |
1000 N/100mm |
| Long-term crush resistance acceptance criteria |
Δα ≤ 0,05 dB prior release, no damage |
| Long-term crush resistance test method |
IEC 60794-1-21:E3A |
| Short-term crush resistance |
2000 N/100mm |
| Short-term crush resistance acceptance criteria |
Δα ≤ 0,05 dB after release, no damage |
| Short-term crush resistance test method |
IEC 60794-1-21:E3A |
| Impact resistance |
10 Nm, 3 impacts, d=20 mm, R=300 mm |
| Impact resistance acceptance criteria |
Δα ≤ 0,05 dB after test, no damage |
| Impact resistance test method |
IEC 60794-1-21:E6 |
| Torsion |
L = 1 m, rotation angle ±180°, 10 cycles |
| Torsion acceptance criteria |
no damage |
| Torsion test method |
IEC 60794-1-21:E7 |
| Repeated bending |
R=20 x cable diameter, 25 cycles |
| Repeated bending acceptance criteria |
Δα ≤ 0,05 dB after test, no damage |
| Repeated bending test method |
EN 60794-1-21:E6 |
| Cable bend |
d=20 x cable diameter, 4 turns, 3 cycles |
| Cable bend acceptance criteria |
Δα ≤ 0,05 dB after test, no damage |
| Cable bend test method |
IEC 60794-1-21:E11A |
| Minimum bend radius in service |
90 mm |
| Minimum bend radius during installation |
130 mm |
Technical Data
| Cable family code |
OT1EL |
| Cable type |
Central loose tube cable |
| Cable version |
n.a. |
| Cable application |
outdoor use |
| DoP number |
D9905 |
| Fiber type |
G.657.A1 |
| Fiber count |
12 |
| Fiber color coding |
1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink |
| Fiber count per tube |
12 |
| Loose tube count |
1 |
| Loose tube diameter |
2,8 mm |
| Armor |
Rodent protection |
| Outer sheath thickness |
1 mm |
| Outer sheath material |
UV stable LDPE |
| Outer sheath color |
black |
| Sheath marking |
Ink-Jet, white |
| Cable outer diameter |
5,8 mm |
| Cable weight |
29.0 kg/km / 19 lbs/1000ft |
| DIN / VDE 0888 code |
A-DQ(ZN)2Y wbg |
| CPR classification |
Fca |