Proizvođač: Reichle & De-Massari
CLT A-DQ(ZN)B2Y
Kataloška oznaka: R851102
Cena: zvati Jed.mere: m PDV: 20 % Garancija: 5 godina
|
Technical Data
Cable family code |
OT1GL |
Cable type |
Central loose tube cable |
Cable application |
outdoor use |
DoP number |
D9907 |
Fiber color coding |
1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink |
Fiber count per tube |
12 |
Loose tube count |
1 |
Loose tube diameter |
2.8 mm |
Armor |
Intensified rodent protection |
Outer sheath thickness |
1.1 mm |
Outer sheath material |
UV stable LDPE |
Outer sheath color |
black |
Sheath marking |
Ink-Jet, white |
Cable outer diameter |
6.5 mm |
Cable weight |
37.0 kg/km / 25 lbs/1000ft |
DIN / VDE 0888 code |
A-DQ(ZN)B2Y |
CPR test method |
EN 50575, EN 13501-6 |
Standard put-up length on drum |
2100 m ± 5% |
CPR classification |
Fca |
Mechanical Data
In-service tensile strength |
600 N |
In-service tensile strength acceptance criteria |
Δα ≤ 0,05 dB |
In-service tensile strength test method |
EN 60794-1-21:E1 |
Installation tensile strength |
1800 N |
Installation tensile strength acceptance criteria |
Δα ≤ 0,05 dB after test |
Installation tensile strength test method |
IEC 60794-1-21:E1 |
Crush resistance long term |
1000 N/100mm |
Long-term crush resistance acceptance criteria |
Δα ≤ 0,05 dB prior release, no damage |
Long-term crush resistance test method |
IEC 60794-1-21:E3A |
Short-term crush resistance |
2000 N/100mm |
Short-term crush resistance acceptance criteria |
Δα ≤ 0,05 dB after release, no damage |
Short-term crush resistance test method |
IEC 60794-1-21:E3A |
Impact resistance |
10 Nm, 3 impacts, d=20 mm, R=300 mm |
Impact resistance acceptance criteria |
Δα ≤ 0,05 dB after test, no damage |
Impact resistance test method |
IEC 60794-1-21:E4 |
Torsion |
L = 1 m, rotation angle ±180°, 10 cycles |
Torsion acceptance criteria |
no damage |
Torsion test method |
IEC 60794-1-21:E7 |
Repeated bending |
R=20 x cable diameter, 25 cycles |
Repeated bending acceptance criteria |
no damage |
Repeated bending test method |
IEC 60794-1-21:E6 |
Cable bend |
d=20 x cable diameter, 4 turns, 3 cycles |
Cable bend acceptance criteria |
Δα ≤ 0,05 dB after test, no damage |
Cable bend test method |
IEC 60794-1-21:E11A |
Minimum bend radius in service |
100 mm |
Minimum bend radius during installation |
130 mm |
Environmental Characteristics
Temperature cycling |
-20 °C +70 °C / -4 °F +158 °F |
Temperature cycling acceptance criteria |
Δα ≤ 0,05 dB |
Temperature cycling test method |
IEC 60794-1-22:F1 |
Reversible temperature cycling |
-25 °C +70 °C / -13 °F +158 °F |
Reversible temperature cycling acceptance criteria |
Δα ≤ 0,15 dB, reversible |
Reversible temperature cycling test method |
IEC 60794-1-22:F1 |
Operation temperature |
-20 °C to +70 °C / -4 °F to +158 °F |
Storage / Transport temperature |
-25 °C to +70 °C / -13 °F to +158 °F |
Thermal load |
1.01 MJ/m |
Flammability vertical cable bundle |
Pass |
Flammability vertical cable bundle test method |
EN 60332-3-22 (cat. A) |
Smoke density |
Pass |
Smoke density test method |
EN 61034-1, EN 61034-2 |
Halogen free, acid gases |
Pass |
Halogen free, acid gases test method |
EN 60754-2 |
2015 / 863 / EU - RoHS 3 |
Pass |
|