Stranded loose tube, blowable Micro cable, NAR-no armor, outdoor-use, UV.HDPE sheath - black, Fca, 1 x 12f = 12 fibers G657A1

Štampa PDF

 

 

linija

 

Proizvođač:  Reichle & De-Massari 

SLT A-DQ(ZN)2Y WBF 

Kataloška oznaka: R856135

 

slika

Cena: zvati 

Jed.mere: m       PDV: 20 % 

Garancija: 5 godina 

 

 

Technical Data 

Cable family code MT6x1,5AH
Cable type Stranded loose tube cable
Cable version Micro cable (blowable)
Cable application "air blown" Microduct outdoor installations
DoP number D9920
Fiber type G.657.A1
Fiber count 12
Fiber color coding 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber count per tube 12
Loose tube count 1
Loose tube diameter 1.55 mm
FRP/coat. CSM nominal thickness [mm] 1.7
Outer sheath thickness 0.5 mm
Outer sheath material UV stable HDPE
Outer sheath color black
Sheath marking Ink-Jet, white
Cable outer diameter 5.7 mm
Cable weight 30.0 kg/km / 20 lbs/1000ft
DIN / VDE 0888 code A-DQ(ZN)2Y nx1,5
Expected lifetime min. 30 years
CPR test method EN 50575, EN 13501-6
Standard put-up length on drum 2100 m ± 5%
CPR classification Fca

Mechanical Data 

Installation tensile strength 600 N
Installation tensile strength acceptance criteria Δα ≤ 0,05 dB after test
Installation tensile strength test method IEC 60794-1-21:E1
Short-term crush resistance 1000 N/100mm
Short-term crush resistance acceptance criteria Δα ≤ 0,05 dB after release, no damage
Short-term crush resistance test method IEC 60794-1-21:E3A
Impact resistance 5 Nm, 3 impacts, d=20 mm, R=300 mm
Impact resistance acceptance criteria Δα ≤ 0,05 dB after test, no damage
Impact resistance test method IEC 60794-1-21:E4
Torsion L = 1 m, rotation angle ±180°, 10 cycles
Torsion acceptance criteria no damage
Torsion test method IEC 60794-1-21:E7
Kink d=40 x cable diameter
Kink acceptance criteria no damage
Kink test method IEC 60794-1-21:E10
Repeated bending R=40 x cable diameter, 25 cycles
Repeated bending acceptance criteria no damage
Cable bend d=40 x cable diameter, 4 turns, 3 cycles
Cable bend acceptance criteria Δα ≤ 0,05 dB after test, no damage
Cable bend test method IEC 60794-1-21:E11A
Minimum bend radius in service 85 mm
Minimum bend radius during installation 115 mm
Loose-tube colour coding 1.red, 2.green - on each layer, rest of tubes white (fillers uncoloured or black)
Fiber color coding 1 .. 12 green, yellow, white, blue, red, violet, brown, pink, black, gray, orange, acqua

Environmental Characteristics 

Temperature cycling -40 °C +70 °C / -40 °F +158 °F
Temperature cycling acceptance criteria Δα ≤ 0,05 dB
Temperature cycling test method IEC 60794-1-22:F1
Operation temperature -40 °C to +70 °C / -40 °F to +158 °F
Storage / Transport temperature 40 °C to +70 °C / +104 °F to +158 °F
Thermal load 0.77 MJ/m

 

 

 

 

 