Technical Data
| Cable family code |
MT6x1,5AH |
| Cable type |
Stranded loose tube cable |
| Cable version |
Micro cable (blowable) |
| Cable application |
"air blown" Microduct outdoor installations |
| DoP number |
D9920 |
| Fiber type |
G.657.A1 |
| Fiber count |
24 |
| Fiber color coding |
1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink |
| Fiber count per tube |
12 |
| Loose tube count |
2 |
| Loose tube diameter |
1.55 mm |
| FRP/coat. CSM nominal thickness [mm] |
1.7 |
| Outer sheath thickness |
0.5 mm |
| Outer sheath material |
UV stable HDPE |
| Outer sheath color |
black |
| Sheath marking |
Ink-Jet, white |
| Cable outer diameter |
5.7 mm |
| Cable weight |
30.0 kg/km / 20 lbs/1000ft |
| DIN / VDE 0888 code |
A-DQ(ZN)2Y nx1,5 |
| Expected lifetime |
min. 30 years |
| CPR test method |
EN 50575, EN 13501-6 |
| Standard put-up length on drum |
2100 m ± 5% |
| CPR classification |
Fca |
Mechanical Data
| Installation tensile strength |
600 N |
| Installation tensile strength acceptance criteria |
Δα ≤ 0,05 dB after test |
| Installation tensile strength test method |
IEC 60794-1-21:E1 |
| Short-term crush resistance |
1000 N/100mm |
| Short-term crush resistance acceptance criteria |
Δα ≤ 0,05 dB after release, no damage |
| Short-term crush resistance test method |
IEC 60794-1-21:E3A |
| Impact resistance |
5 Nm, 3 impacts, d=20 mm, R=300 mm |
| Impact resistance acceptance criteria |
Δα ≤ 0,05 dB after test, no damage |
| Impact resistance test method |
IEC 60794-1-21:E4 |
| Torsion |
L = 1 m, rotation angle ±180°, 10 cycles |
| Torsion acceptance criteria |
no damage |
| Torsion test method |
IEC 60794-1-21:E7 |
| Kink |
d=40 x cable diameter |
| Kink acceptance criteria |
no damage |
| Kink test method |
IEC 60794-1-21:E10 |
| Repeated bending |
R=40 x cable diameter, 25 cycles |
| Repeated bending acceptance criteria |
no damage |
| Cable bend |
d=40 x cable diameter, 4 turns, 3 cycles |
| Cable bend acceptance criteria |
Δα ≤ 0,05 dB after test, no damage |
| Cable bend test method |
IEC 60794-1-21:E11A |
| Minimum bend radius in service |
85 mm |
| Minimum bend radius during installation |
115 mm |
| Loose-tube colour coding |
1.red, 2.green - on each layer, rest of tubes white (fillers uncoloured or black) |
| Fiber color coding |
1 .. 12 green, yellow, white, blue, red, violet, brown, pink, black, gray, orange, acqua |
Environmental Characteristics
| Temperature cycling |
-40 °C +70 °C / -40 °F +158 °F |
| Temperature cycling acceptance criteria |
Δα ≤ 0,05 dB |
| Temperature cycling test method |
IEC 60794-1-22:F1 |
| Operation temperature |
-40 °C to +70 °C / -40 °F to +158 °F |
| Storage / Transport temperature |
40 °C to +70 °C / +104 °F to +158 °F |
| Thermal load |
0.77 MJ/m |