Central loose tube, single sheathed cable, iRP-increased rodent protected, outdoor-use, UV.LDPE sheath - black, Fca, 01 x 24 fibers G657A1

Štampa PDF

 

 

linija

 

Proizvođač:  Reichle & De-Massari 

CLT A-DQ(ZN)B2Y 

Kataloška oznaka: R848355

 

slika

Cena: zvati 

Jed.mere: m       PDV: 20 % 

Garancija: 5 godina 

 

 

Technical Data 

Cable family code OX1GL
Cable type Central loose tube cable
Cable application outdoor use
DoP number D9908
Fiber type G.657.A1
Fiber count 24
Fiber color coding 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink(ring-marked)
Fiber count per tube 24
Loose tube count 1
Loose tube diameter 3.5 mm
Armor Intensified rodent protection
Outer sheath thickness 1.2 mm
Outer sheath material UV stable LDPE
Outer sheath color black
Sheath marking Ink-Jet, white
Cable outer diameter 7.4 mm
Cable weight 50.0 kg/km / 34 lbs/1000ft
DIN / VDE 0888 code A-DQ(ZN)B2Y
CPR test method EN 50575, EN 13501-6
CPR classification Fca

Mechanical Data 

In-service tensile strength 800 N
In-service tensile strength acceptance criteria Δα ≤ 0,05 dB
In-service tensile strength test method IEC 60794-1-21:E1
Installation tensile strength 2000 N
Installation tensile strength acceptance criteria Δα ≤ 0,05 dB after test
Installation tensile strength test method IEC 60794-1-21:E1
Crush resistance long term 1000 N/100mm
Long-term crush resistance acceptance criteria Δα ≤ 0,05 dB prior release, no damage
Long-term crush resistance test method IEC 60794-1-21:E3A
Short-term crush resistance 2000 N/100mm
Short-term crush resistance acceptance criteria Δα ≤ 0,05 dB after release, no damage
Short-term crush resistance test method IEC 60794-1-21:E3A
Impact resistance 10 Nm, 3 impacts, d=20 mm, R=300 mm
Impact resistance acceptance criteria Δα ≤ 0,05 dB after test, no damage
Impact resistance test method IEC 60794-1-21:E4
Torsion L = 1 m, rotation angle ±180°, 10 cycles
Torsion acceptance criteria no damage
Torsion test method EN 60794-1-21:E7
Repeated bending R=20 x cable diameter, 25 cycles
Repeated bending acceptance criteria no damage
Repeated bending test method IEC 60794-1-21:E6
Cable bend d=20 x cable diameter, 4 turns, 3 cycles
Cable bend acceptance criteria Δα ≤ 0,05 dB after test, no damage
Cable bend test method IEC 60794-1-21:E11A
Minimum bend radius in service 110 mm
Minimum bend radius during installation 150 mm

Environmental Characteristics 

Temperature cycling -20 °C +70 °C / -4 °F +158 °F
Temperature cycling acceptance criteria Δα ≤ 0,05 dB
Temperature cycling test method IEC 60794-1-22:F1
Reversible temperature cycling -25 °C +70 °C / -13 °F +158 °F
Reversible temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible
Reversible temperature cycling test method IEC 60794-1-22:F1
Operation temperature -20 °C to +70 °C / -4 °F to +158 °F
Storage / Transport temperature -25 °C to +70 °C / -13 °F to +158 °F
Thermal load 1.33 MJ/m
2015 / 863 / EU - RoHS 3 Pass

 

 

 

 

 